Sets of stones for all types of steels. A set of sharpening stones KosiM be stone for use in steels with a hardness of up to 58 hrts (for example, most kitchen knives, inexpensive folding knives and other knives made of soft steels). A set of sharpening stones KosiM pro oil purposes for steels 58 hrts and more (for example, Japanese steels, M390, X12MF, D2, and other hard stainless and carbon steels). CBN for rough grinding – is used for repairing the cutting edge, when changing the sharpening, and with other robots, if a large amount of metal is required, to complete the process – a form with a skin for polishing burrs. Two types of oil for oil-based sharpening stones (unique Universally suitable for all oil stones, extra oil Used to speed up the sharpening process, but not recommended for the Mow Pro Oil set). Two wooden boxes for storing stones. Platform (podium) for the sharpening system (3 kg).
CO2 ETCO2 Capnograph Respiration Rate End-tidal CO2 Monitor, CA10S NEW. Capnograph adopts sidestream method to measure the end-tidal carbon dioxide, airway respiration rate and other parameters. It can detect pulmonary ventilation function and reflect the circulation and pulmonary blood flow as well as indirectly reflect the alveolar ventilation standard. Meanwhile, it can also detect the blood oxygen saturation and pulse. The Capnograph is applicable for use in pre-hospital emergency transfer, emergency department, ICU, operating room, neonatology, respiratory department and other occasions. The application population is adult, pediatric and neonate patients. 1End-tidal CO2 measurement function. 2Respiration rate measurement function. 3SpO2 measurement function. 4Pulse rate measurement function. 5Over-limit alarm function for EtCO2? Respiration rate, SpO2 and Pulse rate. 6Low battery alarm function. 1Measurement range: 0 150mmHg. 41~70 mmHg:±5% of readings. 71~100 mmHg:±8% of readings. 101~150 mmHg:±10% of readings. 1Measurement range: 30~100 %. 0 ~ 69 %:undefinition. 1Measurement range: 25~250 bpm. 3Accuracy: ±2 bpm or ±2%, whichever is greater. 1Device type: internally powered equipment. 2Degree of protection against electric shock: type BF applied part. 3Degree of protection against ingress of liquid: IPX1. Relative humidity: 30% 75%, no condensation. Power supply: DC 3.7V (rechargeable lithium battries). Input power:? 1.5VA. Food and Drug Administration and state and local regulatory agencies. The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG)with the code 197923, and certified by FDA of United States and CE, TUV of Europe. The Fingertip Pulse Oximeter that is FDA 510K Approved. These charges are buyers’ responsibility. ECG / ECG holter EEG / EEG Holter B-ultrasound. Patient Monitor Fetal doppler Fetal Monitor. Spo2 Monitor Stethoscope Medical Image… Agent in the world! We are look for partners in the world now! Do you want to become our agent in you conutry? Mary # hotmail dot com.