CONTEC FDA&CE ICU CCU ETCO2 Vital Signs Patient Monitor, 7 Parameters CMS8000 Newest. The monitor has abundant functions that can be used for clinical monitoring with adult, pediatric and neonate. Users may select different parameter configuration according to different requirements. The monitor, power supplied by 100-240V~, 50/60Hz, adopts 12.1” color TFT LCD displaying real-time date and waveform. It can synchronously display eight-channel waveform and full monitoring parameters equipped with an optional 48mm thermal recorder. The monitor can be connected to the central monitoring system via wire or wireless network to form a network monitoring system. This device can monitor such parameters as ECG, RESP, NIBP, SpO2, and dual-channel TEMP, etc. It integrates parameter measurement module, display and recorder in one device to form a compact and portable equipment. Its replaceable internal battery brings lot of convenient for patient moving. Standard parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP 1ECG Heart rate(HR) ECG waveform Arrhythmia and ST-segment analysis 2RESP Respiration rate(RR) Respiration waveform 3SpO2 Oxygen saturation(SpO2) Plethysmogram(PLETH) waveform Pulse rate(PR) Bar graph 4NIBP Systolic pressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN) 5TEMP T1, T2, TD 6IBP(optional) CH1:SYS, DIA, MAP CH2:SYS, DIA, MAP IBP waveform 7CO2(optional) EtCO2 InsCO2:Inspired Minimum CO2 AwRR:Air Way Respiration It has abundant functions, such as audible and visual alarm, trend data storage and output, NIBP measurement, alarm event marking and drug concentration calculation, etc. 112.1” TFT color LCD, multi-language interface(Simplified Chinese, Traditional Chinese, English, French, German, Turkish, Spanish, Portuguese, Italian, Dutch, Romanian, Russian, Kazakh, Polish, Czech). 2Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection. 3All-round monitor for adult, pediatric and neonate. 4With standard interface, oxygen graph, trend graph, big character interface and view bed, convenient to observe. 5Finish all operations by keys and knobs. 6Maximum 8-channel waveform synchronous display. 7Display 7-lead ECG waveform on one screen, cascade ECG waveform display 8Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling. 9Heart rate variability (HRV) analysis function 10NIBP measurement mode: Manual/AUTO/STAT, storage for 4800-group NIBP data. 11Review for 71 alarm events of all parameters and 60 arrhythmia alarm events. 12Drug concentration calculation and titration table functions. 13One-touch printing of trend graph 14Connect to Central Monitoring System by 3G, Wi-Fi or wired mode. 15AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring. 16Anti-high frequency surgical unit, defibrillation-proof (special leads are necessary). ECG Lead mode: 3-lead or 5-lead Lead selection: I, II, III, aVR, aVL, aVF, V Waveform: 5-lead, dual-channel 3-lead, single-channel Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV Scan speed: 12.5mm/s, 25 mm/s, 50 mm/s HR: Measurement and alarm range: 15~350 bpm Accuracy: ±1 % or ±1 bpm, whichever is greater Alarm accuracy: ± 2 bpm Resolution: 1 bpm ST-segment monitoring: Measurement and alarm range: -2.0 mV ~ +2.0 mV Accuracy: -0.8 mV~+0.8 mV ±0.04 mV or ±10%, whichever is greater Other range: unspecified Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC Pacemaker: yes? RESP Method: R-F(RA-LL) Impedance Respiration rate: Measurement and alarm range: 0~150 rpm Resolution: 1 rpm Measurement accuracy: ±2 rpm Alarm accuracy: ±3 rpm Apnea alarm: 10~40s Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s? NIBP Method: Oscillometry Mode: Manual/AUTO/STAT Measurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutes Measurement period in STAT mode: 5 minutes Measurement and alarm range: 10 ~ 270 mmHg Resolution: 1 mmHg Cuff pressure accuracy: ±3 mmHg Measurement accuracy: Maximal mean deviation: ±5 mmHg Maximal standard deviation: 8 mmHg Over-pressure protection: Adult mode: 297±3 mmHg Pediatric mode: 240±3 mmHg Neonatal mode: 147±3 mmHg? SpO2 Measurement and alarm range: 0 ~ 100% Resolution: 1% Measurement accuracy: 70%~100%: ±2%; 0%~69%: unspecified? PR Measurement and alarm range: 30 ~ 250 bpm Measurement accuracy: ±2 bpm or ±2%, whichever is greater? TEMP Channel: dual-channel Measurement and alarm range: 0 ~ 50? Resolution: 0.1? Accuracy: ±0.1?? EtCO2 Method: Sidestream or Mainstream Measuring Range: 0~150mmHg Resolution: 0~69 mmHg, 0.1 mmHg 70~150 mmHg, 0.25 mmHg Accuracy: 0~40 mm Hg ±2 mm Hg 41~70 mm Hg ±5% 71~100 mm Hg ±8% 101~150 mm Hg ±10% AwRR Range: 2~150 rpm AwRR Accuracy: ±1BPM Apnea Alarm: Yes? IBP. Channel: dual-channel Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2 Measuring and Alarm Range: -10~300 mmHg Resolution 1 mmHg Accuracy: ±2% or 1mmHg, whichever is greater? Power supply: 100-240V~, 50/60Hz? Safety classification: Class I, type CF defibrillation-proof applied part. 1Adult fingertip SpO2 probe (5-pin) 2Adult NIBP cuff 3NIBP extension tube 4ECG lead cable 5ECG electrode 6Temperature probe 7Power cord 8User Manual. Dimension: 314 mm(L) × 145 mm(W) × 264 mm(H). Weight: 3.9 Kg. Food and Drug Administration and state and local regulatory agencies. The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG)with the code 197923, and certified by FDA of United States and CE, TUV of Europe. The Fingertip Pulse Oximeter that is FDA 510K Approved. These charges are buyers’ responsibility. ECG / ECG holter EEG / EEG Holter B-ultrasound. Patient Monitor Fetal doppler Fetal Monitor. Spo2 Monitor Stethoscope Medical Image… Agent in the world! We are look for partners in the world now! Do you want to become our agent in you conutry?